Medical Gas Chromatography

Send Inquiry

Product Introduction Specification

Model:YSTE-GC7860

 

The YSTE-GC7860 can be equipped with a liquid automatic sampler, which uses control software to control various parameters. This will bring better repeatability and improve work efficiency, while eliminating errors caused by manual sampling.

 

Features

1.8-inch touch screen.

 

2.Gas circuit manually and full electronic gas circuit (EPC/EFC, control is optional,networking communication (Ethernet interface lEEE802.3),computer online full control operation.

 

3.Electronic gas circuit(EPC/EFC) control mode

EPC electronic gas circuit control precision is 0.01mL/min or 0.01Kpa, which ensures better retention time reproducilbility and more consistent and reliable results

EPC working mode: constant current, constant voltage, shunt mode

Program pressure control: 4 stage

EPC working gases: N2, H2, Air, He, Ar EPC control range: pressure 0~0.6kpa flow 0~100sccm or 0~500sccm
EPC control accuracy: pressure 0.01Kpa; Flow rate of 0.01sccm

 

4.Support high-speed heating, the maximum rate of 80°C/min; Suitable for rapid analysis

 

5.Could be up to 450°C, suitable for high boiling point the analysis of the sample

 

6.Support double oven and double rear door opening mode

 

7.Oven temperature increment 1°C, the accuracy of + /-0.01°C, is close to high-grade imported similar products

 

8.External events: 6-way. auxiliary control 2-way.

 

9.Diversified injection system; Packed column injection, capillary S/SL injection, valve injection, automatic liquid injection,automatic headspace injection, splitting injection, thermal desorption injection, purge and capture injection are optional

 

10.Special customized valve system can help users complete complex multidimensional chromatographic analysis tasks. Plus series is a multi-purpose gas chromatography specially designed for multidimensional application analysis and online analysis.

 

11.Rich detector types, up to three detectors can be installed: TCD, HTCD, uTCD, FID, FPD, ECD, NPD, ZD, PDHID, PID, AID

 

12.The program supports multiple flow path sample selection MPV system, with automatic identification valve number,automatic cascade judgment, automatic reset, valve position selection, valve position analysis memory function, up to 32 support sample flow path selection

 

13.Unique network remote transmission and control functions, unattended analysis, decentralized monitoring, centralized control.

 

14.The data can be connected to DCS system to complete the statistics, analysis and monitoring of chromatographic component content and improve the automation level of production process
control

 

15.Temperature control index

 

16.Temperature control circuit number: 8

 

17.Oven temperature index Oven temperature range: room temperature of 4 °C ~ 450°C (increment 1°C) Oven temperature control precision, better than ±0.01°C Oven temperature programming Rising order: 16 order Rising rate setting: 0.1 ~39°C/min (ordinary type); 0.1~80°C/min (high-speed type) Constant temperature time of each order: 0~999min (increment: 0.1min) Programmed cooling: 260°C to 50°C only need 6 minutes

 

18.Sample injector, detector, thermal conductivity pool, methane reformer temperature index;

 

19.Range of temperature: Room temperature of 4°C~ 450°C (increment 1 °C) The accuracy of temperature control: better than ±0.01°C

 

Detector

FID

The collecting pole adopts the original cylindrical structure and quartz nozzle

Limit of detection:≤3x10-12g/s

Baseline Noise: 5x10-14A

Baseline Drift: ≤1x10-13A/30min

Linear: ≥107

Autoignition

 

TCD

Adopt semi-diffused structure

Constant current control mode is adopted for power supply

Sensitivity:S≥3000mv.ml/mg

HTCD High sensitivity thermal conductivity detector S≥10000mv.ml/mg,

Digital amplification 1, 2, 4, 8 times optional

Baseline Noise:≤10μv

Baseline Drift:≤30μv/30min

Linear:≥105

Carrier gas velocity stability:≤1%

Capillary column connecting parts are optional

 

ECD

Limit of detection:≤1x10-14g/s

Linear range: 104

Source: Nj63

 

FPD

Limit of detection: 5x-12g/s(S) (S in methyl parathion) 5x10-13g/s (P) (P in methyl parathion)

Linear range:105(P)103(S)

Maximum service temperature: 350°C

Detection Method: Air-hydrogen flame spectrometry

Optical detector: Top photomultiplier

Multiplier voltage: Max--700V

 

NPD
Limit of detection: (N)≤5x10-12g/s (P)≤5x10-12g/s

Hot Tags: medical gas chromatography, China medical gas chromatography manufacturers, suppliers, factory