Veterinary Monitor VET12H

Veterinary Monitor 12 Inch Veterinary Monitor Features: Professional design for vet: Cats (Small), Dogs (Middle), Horses (Large); 12" color TFT display, high resolution: 800x600dpi; Special NIBP board for vet, alarm range, and software; Special accessories for vet: 3/5 lead ECG cable with...
Send Inquiry

Product Introduction Specification

Veterinary Monitor


12 Inch Veterinary Monitor

Features:

Professional design for vet: Cats (Small), Dogs (Middle), Horses (Large);

12" color TFT display, high resolution: 800x600dpi;

Special NIBP board for vet, alarm range, and software;

Special accessories for vet:

3/5 lead ECG cable with vet limbs clip

SpO2 sensor with tongue and ear clip

NIBP cuff (original Suntech cuff1 2#, 3#, 4#, 5#)

Rectum TEMP sensor

Full touch-screen enables intuitive operation + navigation knob;

SpO2 Pitch Tone Variation;

Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic;

Standby mode for Energy saving and suspend monitoring;

Screen brightness adjustable;

Capture dynamic waveforms;

Built-in rechargeable lithium battery, and battery volume checking;

AC power checking;

Time delay switch-off function keeps the monitor data;

Complete and flexible mounting solution for transportation.


Standard 5 parameters: ECG, SpO2(PR), NIBP, TEMP, RESP
Optional Para: Touchscreen, ECO2, 2-IBP, Suntech NIBP, Masimo/Nellcor SpO2, Multi-gas(AG), Printer, Wall Mount/Trolley

VET-12H Neutral1 1VET-12Hback Neutral1 1

 

Hot Tags: veterinary monitor vet12h, China veterinary monitor vet12h manufacturers, suppliers, factory

Specifications:

ECG:
Lead selection: Standard 5 leads: I, II, III, AVR, AVL, AVF, V
ECG amplification width: 0.05Hz-100 Hz
S-T section monitoring: -2.0mV~2.0mV
Electrode shedding indication: Visual, audible and electric indicate
Scanning speed: 6.25, 12.5, 25, 50mm/SEC
Gain selection: x1/2, x1, x2, x4
ECG calibration: 1mV+5%
Protection Withstand 4000VAC/50Hz voltage isolation;
Alarm: The upper and lower limit of alarm value can be set, automatic memory, and alarm review;
ECG cable:
Standard: Animal specific 3-lead ECG cable


Heart rate:
Detection range of heart rate: 0-350bpm
Resolution: 1bpm
Accuracy: +/-1%


SpO2:
Display: Blood oxygen value, perfusion index, pulse histogram, waveform, pulse value
SpO2 Range: 0%-100% for large animals or small animals
Resolution: 1%
Accuracy: +2%(Undefined below 70%)
Pulse range: 0-300bpm
Pulse accuracy: ±1bpm
Standard sensors: Special probe for animal tongue and ear
Alarm value: The upper and lower limit of alarm value can be set, automatic memory


Pulse rate:
Measurement range: 0~350
Alarm range:
Upper limit: 80 to 350
Lower limit: 20 to 150


NIBP:
Measurement method: Digital automatic oscillometric
Measurement parameters: Systolic pressure, Diastolic pressure, Mean pressure, Pulse rate
Working mode: Manual, automatic, and continuous measurement
Unit: mmHg/KPa Optional
Interval time of automatic measurement: 0~250min adjustable
Overvoltage protection: Hardware and software protection
Measurement range: Large animals: 10mmHg~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~300mmHg
Small animals: 10mmHg~200mmHg
Cuff pressure range: 0~~~~~~~~~~~~~~~~~~~~~~~~~~320 mmHg
Standard cuff: 1#, 2#, 3#, 4#, 5# total SPCs
Aeration time: Less than 6 seconds
Test vent time: Less than 15 seconds


TEMP:
Measurement range: 0°C~50°C
Resolution: 0.1°C Accuracy: +/-01°C
Standard probe: Esophagus/rectum temp probe
Alarm: Upper and lower limit value can be set, automatic memory


RESP:
Measurement method: Thoracic impedance
Respiration rate (RR):
A). Measurement range: 0–120bpm
B). Measurement accuracy: ±1bpm or 5%bp
Alarm: Upper and lower limit value can be set, automatic memory


2-IBP(Optional):
Number of channels: 2
Pressure sensor nominal sensitivity: 5uV/V/ mmHg, error ±2%
Pressure sensor input impedance, output impedance: 300Ω ~3000Ω
Static pressure measurement range: -50~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~+300mmHg (Up to 350 mmHg)
Static pressure measurement error:
±1mmHg or +1%, greater (Not including probe)
±4mmHg or ±4%, greater (Including probe)
Dynamic pressure measurement range: -50~+300mmHg
Dynamic pressure measurement error: ±4mmHg or ±4% of reading (greater)
Vessel types: ART, PA/CVP/RAP/LAP/ICP
Scope of stress test:
ART: 0~300mmHg
AP/RAP/LAP/ICP: -50~~~~~~~~~~~~~~~~~~~~~~~120 mmHg
Resolution: 1mmHg


EtCO2(Optional):
Sampling Type: Mainstream/Side stream
Sampling Velocity:
Range: 50-150 ml/min
Accuracy: ±20%
Default value: 75ml/min
Measurement principle: Non-spectral infrared, double channel, no moving parts(degassing pump)